GW Instek LCR-7000 precision LCR meter with a 5-inch touch display, five models from 10 Hz to 2, 20, 100, 200 or 300 kHz, 0.05% basic accuracy, frequency sweep and internal ±5 V DC bias. Available in India from GSAS Micro Systems.

Test Frequency

10 Hz to 2 / 20 / 100 / 200 / 300 kHz (model dependent)

Basic Accuracy

0.05% (Slow/Med), 0.1% (Fast)

Measurement Speed

Fast 25 ms / Med 100 ms / Slow 333 ms

Test Signal Level

10 mV to 2 V / 100 µA to 20 mA

Internal DC Bias

±5 V

Bin Sorting

9 BIN + 1 AUX (10 total)

Display

5-inch touch LCD

Interfaces

RS-232C, USB Type-C device, LAN (SCPI); Handler, USB Host

Authorized partner since 2012
Local FAE & application engineering
Hands-on training & integration
Manufacturer warranty

About LCR-7000 Series Precision LCR Meter

The GW Instek LCR-7000 Series is a benchtop precision LCR meter with a 5-inch touch display, measuring passive components from 10 Hz up to 300 kHz with 0.05% basic accuracy. It shows up to four parameters at once, sweeps two parameters against frequency, applies an internal ±5 V DC bias, and sorts parts into 9 BIN + 1 AUX for incoming inspection and production. Five models cover maximum test frequencies of 2, 20, 100, 200 and 300 kHz.

GW Instek LCR-7300 precision LCR meter with 5-inch touch display, available in India from GSAS Micro Systems

LCR-7000 model lineup

ModelTest frequency
LCR-700210 Hz to 2 kHz
LCR-702010 Hz to 20 kHz
LCR-710010 Hz to 100 kHz
LCR-720010 Hz to 200 kHz
LCR-730010 Hz to 300 kHz

All models set frequency continuously within their range (±0.01%, 4-digit resolution) and share the same accuracy, test signal, bias, sorting and interface specifications.

Key specifications

SpecificationLCR-7000 Series
Basic accuracy0.05% (Slow/Med), 0.1% (Fast)
Measurement speedFast 25 ms / Med 100 ms / Slow 333 ms
Output impedance30 Ω / 50 Ω / 100 Ω selectable
AC test voltage10.00 mV to 2.00 V
AC test current100.0 µA to 20.00 mA
Internal DC bias±5 V (0.5% + 0.005 V)
DCR measurement+2 V, 0.066 A max, 30 Ω fixed output impedance
Measurement combinations16 (Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR) + 2 monitor parameters
List mode10 steps (frequency, voltage, current)
Sweep2 parameters vs frequency, linear/log, more than 250 points
BIN function9 BIN + 1 AUX; ABS/PER/SEQ comparators
Other functionsAuto Level Control (ALC), GO/NoGO, averaging 1 to 256, OPEN/SHORT correction (full frequency or spot)
Memory10 setup files; 10,000 measured records (CSV); USB storage
Display5-inch touch LCD
InterfacesSCPI over RS-232, USB Type-C device and LAN; Handler; USB Host
Power / size / weightAC 100 V to 240 V, 15 W max; 256 × 101 × 315 mm; approx. 3 kg

Touch operation and frequency sweep

The 5-inch touch display shows setting conditions, the primary and secondary results and two monitor parameters on one screen, and GO/NoGO mode adds a PASS/FAIL verdict. The sweep function plots two parameters against frequency, so you can observe how a component’s characteristics trend across the band or check a specific frequency point. The 10-step list mode checks fixed frequency, voltage and current points in one cycle.

Bias, ALC and correction

GW Instek provides Auto Level Control (ALC) to meet the test-voltage requirements of MLCC measurement. The internal ±5 V DC bias covers bias-dependent capacitors; for higher bias, GW Instek offers the LCR-16 ±45 V DC bias voltage box and the LCR-17 ±2.5 A DC bias current box as factory options. OPEN/SHORT correction across the full frequency range or at a spot frequency removes fixture and lead parasitics.

Sorting and system integration

The Handler interface and the 9 BIN + 1 AUX comparator connect the LCR-7000 to a component sorter for production screening. RS-232C, USB Type-C and LAN carry SCPI commands for automated test, and GW Instek provides PC software for logging results. Test fixtures include the LCR-06B Kelvin clip lead (standard accessory), the LCR-05 axial/radial fixture, and the LCR-08A and LCR-15 SMD fixtures. The GRA-459 kit mounts the meter in a 19-inch 2U rack.

Applications

  • Passive component characterisation in R&D and engineering test.
  • Incoming quality inspection of capacitors, inductors and resistors.
  • Production sorting through the BIN comparator and Handler interface.
  • Power magnetics: inductance, DCR and frequency sweeps, with DC bias current through the optional LCR-17 box.

Buy the LCR-7000 in India from GSAS Micro Systems

GSAS Micro Systems is an authorized GW Instek engineering partner for Karnataka, Andhra Pradesh and Telangana, supporting customers across India. We help you pick the frequency grade and fixtures for your parts, arrange demonstrations, and provide GST-compliant quotations and calibration support for teams in Bengaluru, Hyderabad, Chennai, Pune, Mumbai and Delhi NCR. Request a quote or read our LCR-7000 and GPM-8340 launch post.

Common questions about LCR-7000 Series Precision LCR Meter

What frequency range does the LCR-7000 series cover?
Every model starts at 10 Hz. The maximum test frequency is 2 kHz on the LCR-7002, 20 kHz on the LCR-7020, 100 kHz on the LCR-7100, 200 kHz on the LCR-7200 and 300 kHz on the LCR-7300. Test frequency is set continuously within the range with ±0.01% accuracy.
How fast and how accurate is the LCR-7000?
Basic accuracy is 0.05% at Slow and Medium speed and 0.1% at Fast. The measurement time is 25 ms at Fast, 100 ms at Medium and 333 ms at Slow.
Can the LCR-7000 apply DC bias?
Yes. It has an internal DC bias voltage of ±5 V. GW Instek also offers factory options for higher bias: the LCR-16 ±45 V DC bias voltage box and the LCR-17 ±2.5 A DC bias current box.
What does the sweep function do?
The sweep mode plots two measurement parameters against frequency on linear or log axes, with more than 250 points, cursors, and markers for the maximum and minimum points. Results can be saved as CSV data and BMP screen captures.
How do I buy the GW Instek LCR-7000 in India?
GSAS Micro Systems is an authorized GW Instek engineering partner for Karnataka, Andhra Pradesh and Telangana, supporting customers across India. Request a quote with your component type and highest test frequency for INR pricing, fixture recommendations and a GST-compliant quotation.

Interested in LCR-7000 Series Precision LCR Meter?

Get pricing, an evaluation unit, or a technical consultation from our application engineers.

Request a Quote Demo