GPT-9800/9900 Series
Safety TestersGW Instek GPT-9800/9900 hipot tester and electrical safety tester, AC withstand to 5 kV, DC to 6 kV, insulation resistance to 50 GΩ and ground bond to 32 A, with true-RMS leakage current measurement (1 µA resolution) for production safety testing. Available in India from GSAS Micro Systems, the authorized GW Instek engineering partner, with INR/GST quotes, calibration and local demos.
AC Test Capacity
200 VA (9800) / 500 VA (9900)
AC Withstand
0.050–5.000 kV (40 mA / 100 mA max)
DC Withstand
0.050–6.000 kV (10 mA / 20 mA max)
Insulation Resistance
50 V–1000 V, up to 9500 MΩ / 50 GΩ
Ground Bond
3–30 A / 3–32 A AC, 10–650 mΩ
Leakage Current
True RMS, 1 µA (0.001 mA) resolution
Voltage Setting
2 V per step
Display
240×64 ice blue dot matrix LCD
Overview
About GPT-9800/9900 Series
The GW Instek GPT-9800/9900 Series is a family of production-grade hipot testers and electrical safety testers that combine AC withstand, DC withstand, insulation resistance and ground bond testing in a single bench instrument. Built on a high-efficiency PWM amplifier platform, the GPT-9800 delivers 200 VA AC test capacity and the GPT-9900 delivers 500 VA, both with true-RMS leakage current measurement down to 1 µA resolution for accurate pass/fail judgment against tight safety limits.
The series spans eight models across two power platforms. The GPT-9804 and GPT-9904 are 4-in-1 testers (AC withstand + DC withstand + insulation resistance + ground bond); stepping down, the GPT-9803 / GPT-9903A add insulation resistance, the GPT-9802 / GPT-9902A add DC withstand, and the GPT-9801 / GPT-9901A are AC-withstand-only leakage current testers. All models share the same 6 kV DC withstand range, zero-crossing turn-on, ARC detection and 240×64 ice blue dot matrix LCD.

A hipot tester for AC and DC dielectric withstand testing
As a hipot tester, the GPT-9800/9900 applies AC withstand voltage from 0.050 kV to 5.000 kV and DC withstand voltage from 0.050 kV to 6.000 kV, set in fine 2 V steps. On the 200 VA GPT-9800, AC withstand current reaches 40 mA (200 VA at 5 kV); on the 500 VA GPT-9900 it reaches 100 mA (500 VA at 5 kV) for larger DUTs and higher charging currents. DC withstand current is up to 10 mA (GPT-9800) or 20 mA (GPT-9900). The adjustable ramp-up time (0.1 s–999.9 s) lets the test voltage rise gradually to protect the device under test, while the test timer (OFF, 0.5 s–999.9 s) and upper/lower judgment limits define each step. Zero-crossing turn-on ensures output always starts at the zero crossing of the sine wave, eliminating surge transients that cause false failures on sensitive DUTs.
Leakage current tester with true-RMS measurement
For accurate dielectric withstand verification, the GPT-9800/9900 measures leakage current as a true-RMS value with 1 µA (0.001 mA) best resolution and ±(1.5% of reading + 30 µA) accuracy. The AC withstand current measurement range runs from 0.001 mA to 40.0 mA (GPT-9800) or 0.001 mA to 100.0 mA (GPT-9900), making the series a precise leakage current tester for production lines where small leakage readings on non-sinusoidal waveforms must be judged reliably. The window-comparator method gives clear PASS/FAIL judgment with high-intensity status indication so operators read results at a glance, even in a noisy factory environment.
Insulation resistance and ground bond testing
The 3-in-1 and 4-in-1 models add insulation resistance (IR) testing with a DC test voltage adjustable from 50 V to 1000 V in 50 V steps. The GPT-9800 measures IR from 1 MΩ to 9500 MΩ, while the higher-power GPT-9900 extends measurement up to 50 GΩ for high-impedance insulation. The 4-in-1 GPT-9804 and GPT-9904 also perform ground bond testing with an AC output current range of 3.00 A to 30.00 A (GPT-9800) or 3.00 A to 32.00 A (GPT-9900) and a resistance measurement range of 10 mΩ to 650.0 mΩ. Open-circuit detection on the ground bond terminals checks that the test leads are properly connected before the test starts, ensuring accurate measurement of protective-earth continuity.
Built for safe, reliable production safety testing
Throughout each test cycle the GPT-9800/9900 protects both operator and DUT. ARC detection automatically cuts off the output within 150 µs on an abnormal voltage or current-limit trip, and the tester automatically discharges the DUT after each test to remove residual high voltage. A safety INTERLOCK function adds double protection by inhibiting high-voltage output when the interlock key is removed. The high-efficiency PWM amplifier isolates the output from input AC-source fluctuation and reduces heat generation during continuous production testing. Up to 100 memory blocks store single-step test conditions, and AUTO mode chains up to 16 manual steps into an automated multi-step safety routine, ideal for unattended sequencing of ACW, DCW, IR and GB tests.
GPT-9800/9900 series specifications
| Specification | GPT-9800 Series | GPT-9900 Series |
|---|---|---|
| AC test capacity | 200 VA | 500 VA |
| AC withstand voltage | 0.050–5.000 kV | 0.050–5.000 kV |
| AC withstand max current | 40 mA (200 VA at 5 kV) | 100 mA (500 VA at 5 kV) |
| AC current measurement range | 0.001–40.0 mA | 0.001–100.0 mA |
| DC withstand voltage | 0.050–6.000 kV | 0.050–6.000 kV |
| DC withstand max current | 10 mA | 20 mA |
| Insulation resistance test voltage | 50–1000 V (50 V steps) | 50–1000 V (50 V steps) |
| Insulation resistance range | 1 MΩ – 9500 MΩ | 0.001 GΩ – 50.00 GΩ |
| Ground bond current (4-in-1 model) | 3.00–30.00 A AC | 3.00–32.00 A AC |
| Ground bond resistance range | 10 mΩ – 650.0 mΩ | 10 mΩ – 650.0 mΩ |
| Current measurement | True RMS, 1 µA (0.001 mA) resolution | True RMS, 1 µA (0.001 mA) resolution |
| Voltage setting resolution | 2 V per step | 2 V per step |
| Ramp-up time | 0.1–999.9 s | 0.1–999.9 s |
| Test timer | OFF, 0.5–999.9 s | OFF, 0.5–999.9 s |
| Memory | 100 blocks (MANU) / 100 AUTO, 16 steps | 100 blocks (MANU) / 100 AUTO, 16 steps |
| Display | 240×64 ice blue dot matrix LCD | 240×64 ice blue dot matrix LCD |
| Interfaces | RS-232C, USB (device), Signal I/O, remote terminal, GPIB (optional) | RS-232C, USB (device), Signal I/O, remote terminal, GPIB (optional) |
| AC input | 100/120/220/230 V ±10%, 50/60 Hz | 100/120/220/230 V ±10%, 50/60 Hz |
GPT-9800/9900 model lineup
| Model | AC Capacity | Test Functions | Insulation Resistance | Ground Bond Current |
|---|---|---|---|---|
| GPT-9801 | 200 VA | ACW | - | - |
| GPT-9802 | 200 VA | ACW + DCW | - | - |
| GPT-9803 | 200 VA | ACW + DCW + IR | up to 9500 MΩ | - |
| GPT-9804 | 200 VA | ACW + DCW + IR + GB | up to 9500 MΩ | 3.00–30.00 A |
| GPT-9901A | 500 VA | ACW | - | - |
| GPT-9902A | 500 VA | ACW + DCW | - | - |
| GPT-9903A | 500 VA | ACW + DCW + IR | up to 50 GΩ | - |
| GPT-9904 | 500 VA | ACW + DCW + IR + GB | up to 50 GΩ | 3.00–32.00 A |
ACW = AC withstanding voltage, DCW = DC withstanding voltage, IR = insulation resistance, GB = ground bond. GSAS helps you select the model whose test functions and power capacity match your applicable safety standard with margin to spare.
Applications
The GPT-9800/9900’s combination of AC/DC withstand, insulation resistance and ground bond testing makes it well suited to:
- Production-line electrical safety testing: routine dielectric withstand (hipot) and ground continuity checks on finished electrical and electronic products.
- Consumer electronics and household appliances: ACW/DCW and leakage current verification to IEC, EN, UL, CSA, GB and JIS test items.
- Industrial equipment and power supplies: high-capacity 500 VA withstand testing of transformers, motors and larger assemblies with the GPT-9900.
- Insulation and protective-earth verification: insulation resistance up to 50 GΩ and ground bond up to 32 A for two-pole and Class-I appliances.
- Incoming inspection and QA labs: automated multi-step ACW/DCW/IR/GB sequences with PASS/FAIL judgment and 100-block memory.
The GPT-9800/9900 series supports engineering and manufacturing teams in electronics manufacturing, appliance and consumer electronics production, power electronics, and electrical safety / compliance labs where reliable, high-throughput safety testing matters.
Hipot tester price in India: buy the GPT-9800/9900 from GSAS Micro Systems
GSAS Micro Systems is the authorized GW Instek engineering partner in India. We supply the full GPT-9800 and GPT-9900 range, from AC-only withstand testers to 4-in-1 ACW/DCW/IR/GB units, with model-selection guidance, hands-on demonstrations, GST-compliant quotations, calibration with maintained traceability and post-sales application support. Engineering, quality and production teams across Bengaluru, Hyderabad, Chennai, Pune, Mumbai and Delhi NCR rely on GSAS for fast access and local support. Contact GSAS or request a quote to get the GPT-9800/9900 hipot tester price in India and order with delivery nationwide.
Blog
GW Instek Insights
AI Data Center Testing: Power Shelves, Busbars, Burn-In and Optics
AI racks fail on the bench long before they fail in the field. How AI data center infrastructure is actually tested: server power shelves and CRPS supplies, 48V busbars, battery backup units, DC-DC stages, burn-in, thermal validation, high-speed switches, and optical transceivers, mapped to the GW Instek instruments GSAS supplies across India.
Testing High-Power UPS, Solar Inverters and Power Electronics: Inside the GW Instek AEL-5000 AC/DC Electronic Load
India's UPS, solar-inverter and power-electronics makers need load testing that behaves like the real world: non-linear, high-power and scalable. Here is how the GW Instek AEL-5000 AC/DC electronic load covers it, from 1.875 kW on the bench to 540 kW in a three-phase array.
Automated EV Charger Test Bench in India: GW Instek AC Source, DC Load and Battery Emulator
A walkthrough of an automated test bench that validates a CAN-controlled EV scooter charger across the full Indian grid envelope. GW Instek's APS-7200 AC source, PEL-3111AH DC load and GPP-7250 battery emulator combine with a Total Phase Komodo CAN Duo BMS emulator for unattended, repeatable charger validation, designed, integrated and scripted in India by GSAS.
Related products
More from GW Instek
All GW Instek products →
GPT-15000 Series
Electrical safety tester with AC/DC withstand, insulation resistance, ground bond, and leakage current testing. Available in India from GSAS with hands-on application engineering and local support.
View GPT-15000 Series →
GPT-12004: 200 VA Electrical Safety Analyzer (AC/DC/IR/GB + Continuity)
GW Instek GPT-12004 is the top model of the GPT-12000 series, 200 VA AC test capacity with AC withstand, DC withstand, insulation resistance, ground bond, and continuity testing. 7-inch TFT LCD, controllable ramp, 47 µF capacitive load capability, IEC 61010-2-034 compliant. Available in India from GSAS Micro Systems for production safety compliance lines.
View GPT-12004: 200 VA Electrical Safety Analyzer (AC/DC/IR/GB + Continuity) →
GPT-12000 Series
Electrical safety analyzer with 200VA AC capacity, 7-inch color LCD, and AC/DC/IR/GB testing for production compliance verification. Available in India from GSAS Micro Systems.
View GPT-12000 Series →FAQ
Common questions about GPT-9800/9900 Series
How much does the GPT-9800-series cost in India?
What is the difference between the GPT-9800 and GPT-9900 series?
Which GPT-9800/9900 model performs AC withstand, DC withstand, insulation resistance and ground bond?
Does the GPT-9800/9900 measure true-RMS leakage current?
What safety standards does the GPT-9800/9900 support?
How do I buy the GW Instek GPT-9800/9900 in India?
Interested in GPT-9800/9900 Series?
Get pricing, an evaluation unit, or a technical consultation from our application engineers.