GPT-9800/9900 Series
Safety TestersGW Instek GPT-9800/9900 hipot tester and electrical safety tester, AC withstand to 5 kV, DC to 6 kV, insulation resistance to 50 GΩ and ground bond to 32 A, with true-RMS leakage current measurement (1 µA resolution) for production safety testing. Available in India from GSAS Micro Systems, an authorized GW Instek engineering partner, with INR/GST quotes, calibration and local demos.
AC Test Capacity
200 VA (9800) / 500 VA (9900)
AC Withstand
0.050–5.000 kV (40 mA / 100 mA max)
DC Withstand
0.050–6.000 kV (10 mA / 20 mA max)
Insulation Resistance
50 V–1000 V, up to 9500 MΩ / 50 GΩ
Ground Bond
3–30 A / 3–32 A AC, 10–650 mΩ
Leakage Current
True RMS, 1 µA (0.001 mA) resolution
Voltage Setting
2 V per step
Display
240×64 ice blue dot matrix LCD
Overview
About GPT-9800/9900 Series
The GW Instek GPT-9800/9900 Series is a family of production-grade hipot testers and electrical safety testers that combine AC withstand, DC withstand, insulation resistance and ground bond testing in a single bench instrument. Built on a high-efficiency PWM amplifier platform, the GPT-9800 delivers 200 VA AC test capacity and the GPT-9900 delivers 500 VA, both with true-RMS leakage current measurement down to 1 µA resolution for accurate pass/fail judgment against tight safety limits.
The series spans eight models across two power platforms. The GPT-9804 and GPT-9904 are 4-in-1 testers (AC withstand + DC withstand + insulation resistance + ground bond); stepping down, the GPT-9803 / GPT-9903A add insulation resistance, the GPT-9802 / GPT-9902A add DC withstand, and the GPT-9801 / GPT-9901A are AC-withstand-only leakage current testers. All models share the same 6 kV DC withstand range, zero-crossing turn-on, ARC detection and 240×64 ice blue dot matrix LCD.

A hipot tester for AC and DC dielectric withstand testing
As a hipot tester, the GPT-9800/9900 applies AC withstand voltage from 0.050 kV to 5.000 kV and DC withstand voltage from 0.050 kV to 6.000 kV, set in fine 2 V steps. On the 200 VA GPT-9800, AC withstand current reaches 40 mA (200 VA at 5 kV); on the 500 VA GPT-9900 it reaches 100 mA (500 VA at 5 kV) for larger DUTs and higher charging currents. DC withstand current is up to 10 mA (GPT-9800) or 20 mA (GPT-9900). The adjustable ramp-up time (0.1 s–999.9 s) lets the test voltage rise gradually to protect the device under test, while the test timer (OFF, 0.5 s–999.9 s) and upper/lower judgment limits define each step. Zero-crossing turn-on ensures output always starts at the zero crossing of the sine wave, eliminating surge transients that cause false failures on sensitive DUTs.
Leakage current tester with true-RMS measurement
For accurate dielectric withstand verification, the GPT-9800/9900 measures leakage current as a true-RMS value with 1 µA (0.001 mA) best resolution and ±(1.5% of reading + 30 µA) accuracy. The AC withstand current measurement range runs from 0.001 mA to 40.0 mA (GPT-9800) or 0.001 mA to 100.0 mA (GPT-9900), making the series a precise leakage current tester for production lines where small leakage readings on non-sinusoidal waveforms must be judged reliably. The window-comparator method gives clear PASS/FAIL judgment with high-intensity status indication so operators read results at a glance, even in a noisy factory environment.
Insulation resistance and ground bond testing
The 3-in-1 and 4-in-1 models add insulation resistance (IR) testing with a DC test voltage adjustable from 50 V to 1000 V in 50 V steps. The GPT-9800 measures IR from 1 MΩ to 9500 MΩ, while the higher-power GPT-9900 extends measurement up to 50 GΩ for high-impedance insulation. The 4-in-1 GPT-9804 and GPT-9904 also perform ground bond testing with an AC output current range of 3.00 A to 30.00 A (GPT-9800) or 3.00 A to 32.00 A (GPT-9900) and a resistance measurement range of 10 mΩ to 650.0 mΩ. Open-circuit detection on the ground bond terminals checks that the test leads are properly connected before the test starts, ensuring accurate measurement of protective-earth continuity.
Built for safe, reliable production safety testing
Throughout each test cycle the GPT-9800/9900 protects both operator and DUT. ARC detection automatically cuts off the output within 150 µs on an abnormal voltage or current-limit trip, and the tester automatically discharges the DUT after each test to remove residual high voltage. A safety INTERLOCK function adds double protection by inhibiting high-voltage output when the interlock key is removed. The high-efficiency PWM amplifier isolates the output from input AC-source fluctuation and reduces heat generation during continuous production testing. Up to 100 memory blocks store single-step test conditions, and AUTO mode chains up to 16 manual steps into an automated multi-step safety routine, ideal for unattended sequencing of ACW, DCW, IR and GB tests.
GPT-9800/9900 series specifications
| Specification | GPT-9800 Series | GPT-9900 Series |
|---|---|---|
| AC test capacity | 200 VA | 500 VA |
| AC withstand voltage | 0.050–5.000 kV | 0.050–5.000 kV |
| AC withstand max current | 40 mA (200 VA at 5 kV) | 100 mA (500 VA at 5 kV) |
| AC current measurement range | 0.001–40.0 mA | 0.001–100.0 mA |
| DC withstand voltage | 0.050–6.000 kV | 0.050–6.000 kV |
| DC withstand max current | 10 mA | 20 mA |
| Insulation resistance test voltage | 50–1000 V (50 V steps) | 50–1000 V (50 V steps) |
| Insulation resistance range | 1 MΩ – 9500 MΩ | 0.001 GΩ – 50.00 GΩ |
| Ground bond current (4-in-1 model) | 3.00–30.00 A AC | 3.00–32.00 A AC |
| Ground bond resistance range | 10 mΩ – 650.0 mΩ | 10 mΩ – 650.0 mΩ |
| Current measurement | True RMS, 1 µA (0.001 mA) resolution | True RMS, 1 µA (0.001 mA) resolution |
| Voltage setting resolution | 2 V per step | 2 V per step |
| Ramp-up time | 0.1–999.9 s | 0.1–999.9 s |
| Test timer | OFF, 0.5–999.9 s | OFF, 0.5–999.9 s |
| Memory | 100 blocks (MANU) / 100 AUTO, 16 steps | 100 blocks (MANU) / 100 AUTO, 16 steps |
| Display | 240×64 ice blue dot matrix LCD | 240×64 ice blue dot matrix LCD |
| Interfaces | RS-232C, USB (device), Signal I/O, remote terminal, GPIB (optional) | RS-232C, USB (device), Signal I/O, remote terminal, GPIB (optional) |
| AC input | 100/120/220/230 V ±10%, 50/60 Hz | 100/120/220/230 V ±10%, 50/60 Hz |
GPT-9800/9900 model lineup
| Model | AC Capacity | Test Functions | Insulation Resistance | Ground Bond Current |
|---|---|---|---|---|
| GPT-9801 | 200 VA | ACW | - | - |
| GPT-9802 | 200 VA | ACW + DCW | - | - |
| GPT-9803 | 200 VA | ACW + DCW + IR | up to 9500 MΩ | - |
| GPT-9804 | 200 VA | ACW + DCW + IR + GB | up to 9500 MΩ | 3.00–30.00 A |
| GPT-9901A | 500 VA | ACW | - | - |
| GPT-9902A | 500 VA | ACW + DCW | - | - |
| GPT-9903A | 500 VA | ACW + DCW + IR | up to 50 GΩ | - |
| GPT-9904 | 500 VA | ACW + DCW + IR + GB | up to 50 GΩ | 3.00–32.00 A |
ACW = AC withstanding voltage, DCW = DC withstanding voltage, IR = insulation resistance, GB = ground bond. GSAS helps you select the model whose test functions and power capacity match your applicable safety standard with margin to spare.
Applications
The GPT-9800/9900’s combination of AC/DC withstand, insulation resistance and ground bond testing makes it well suited to:
- Production-line electrical safety testing: routine dielectric withstand (hipot) and ground continuity checks on finished electrical and electronic products.
- Consumer electronics and household appliances: ACW/DCW and leakage current verification to IEC, EN, UL, CSA, GB and JIS test items.
- Industrial equipment and power supplies: high-capacity 500 VA withstand testing of transformers, motors and larger assemblies with the GPT-9900.
- Insulation and protective-earth verification: insulation resistance up to 50 GΩ and ground bond up to 32 A for two-pole and Class-I appliances.
- Incoming inspection and QA labs: automated multi-step ACW/DCW/IR/GB sequences with PASS/FAIL judgment and 100-block memory.
The GPT-9800/9900 series supports engineering and manufacturing teams in electronics manufacturing, appliance and consumer electronics production, power electronics, and electrical safety / compliance labs where reliable, high-throughput safety testing matters.
Hipot tester price in India: buy the GPT-9800/9900 from GSAS Micro Systems
GSAS Micro Systems is an authorized GW Instek engineering partner in India. We supply the full GPT-9800 and GPT-9900 range, from AC-only withstand testers to 4-in-1 ACW/DCW/IR/GB units, with model-selection guidance, hands-on demonstrations, GST-compliant quotations, calibration with maintained traceability and post-sales application support. Engineering, quality and production teams across Bengaluru, Hyderabad, Chennai, Pune, Mumbai and Delhi NCR rely on GSAS for fast access and local support. Contact GSAS or request a quote to get the GPT-9800/9900 hipot tester price in India and order with delivery nationwide.
Blog
GW Instek Insights
Battery Simulator vs Battery Emulator: Hardware for BMS and Pack Testing
The bench instrument whose terminals behave like a battery pack, why a plain DC supply leaves BMS code paths unexercised, and the capability list to specify against. Worked through the GW Instek RBS Series battery simulation function.
BESS Test Benches: Rack-Level Charge and Discharge Qualification
The bench that qualifies a storage rack: which voltage classes rack buses land in, the current envelope at top of charge, parallel growth in the class you buy first, and cycling that runs unattended for weeks.
Motor Drive Test Benches: DC Bus Supply and Regenerative Braking
A motor drive bench powered at its DC link terminals needs a bus that supplies the drive and takes energy back when the motor brakes. How one bidirectional source, sized against the real bus voltage, replaces the supply, blocking diode and load.
Related products
More from GW Instek
All GW Instek products →
GPT-15000 Series
Electrical safety tester with AC/DC withstand, insulation resistance, ground bond, and leakage current testing. Available in India from GSAS with hands-on application engineering and local support.
View GPT-15000 Series →
GPT-12004: 200 VA Electrical Safety Analyzer (AC/DC/IR/GB + Continuity)
GW Instek GPT-12004 is the top model of the GPT-12000 series, 200 VA AC test capacity with AC withstand, DC withstand, insulation resistance, ground bond, and continuity testing. 7-inch TFT LCD, controllable ramp, 47 µF capacitive load capability, IEC 61010-2-034 compliant. Available in India from GSAS Micro Systems for production safety compliance lines.
View GPT-12004: 200 VA Electrical Safety Analyzer (AC/DC/IR/GB + Continuity) →
GPT-12000 Series
Electrical safety analyzer with 200VA AC capacity, 7-inch color LCD, and AC/DC/IR/GB testing for production compliance verification. Available in India from GSAS Micro Systems.
View GPT-12000 Series →FAQ
Common questions about GPT-9800/9900 Series
How much does the GPT-9800-series cost in India?
What is the difference between the GPT-9800 and GPT-9900 series?
Which GPT-9800/9900 model performs AC withstand, DC withstand, insulation resistance and ground bond?
Does the GPT-9800/9900 measure true-RMS leakage current?
What safety standards does the GPT-9800/9900 support?
How do I buy the GW Instek GPT-9800/9900 in India?
Interested in GPT-9800/9900 Series?
Get pricing, an evaluation unit, or a technical consultation from our application engineers.