PEL-2000A Series
Electronic LoadsGW Instek PEL-2000A programmable DC electronic load, a modular, multi-channel DC load (2- or 4-slot mainframe with plug-in modules) covering 0–500 V, up to 70 A and 350 W per module, with CC/CR/CV/CP modes, dynamic and sequence functions, and up to 7 kW system capacity. Available in India from GSAS Micro Systems, an authorized GW Instek engineering partner, with INR/GST quotation, demonstration, calibration and application support.
Architecture
Modular: 2-slot (PEL-2002A) / 4-slot (PEL-2004A) mainframe + plug-in modules
Voltage
0–80 V (modules) / 0–500 V (PEL-2041A)
Current
Up to 0–70 A per module
Power
Up to 350 W per module · 1.4 kVA per mainframe · 7 kW chained
Modes
CC, CR, CV, CV+CC, CP (static & dynamic)
Slew Rate
Up to 2.8 A/µs
Dynamic Mode
25 µs minimum step (T1/T2 0.025 ms–30 s)
Protection
OCP, OVP, OPP, OTP, RVP, UVP
Overview
About PEL-2000A Series
The GW Instek PEL-2000A Series is a modular, multi-channel programmable DC electronic load built for power-supply design, quality inspection and characteristic certification. Instead of a single fixed box, it uses a mainframe-and-module structure: the PEL-2002A holds two load modules and the PEL-2004A holds four. Choose your modules to match the job, and the system covers everything from low-power dual-rail validation up to 0–500 V, 0–70 A and 350 W per module: with a fully loaded mainframe sinking up to 1.4 kVA and up to five linked mainframes reaching about 7 kW of total load capacity.
Every module supports CC, CR, CV, CV+CC and CP operating modes (constant current and constant resistance also run in dynamic mode), making the PEL-2000A a flexible DC electronic load for source validation, transient-response testing and automated production screening.

A modular DC electronic load: mainframe plus plug-in modules
The PEL-2000A is not a standalone load; its strength is configurability. You pick a 2-slot PEL-2002A or 4-slot PEL-2004A mainframe (which holds the master controller, display and interfaces) and then fit the load modules your bench needs. Modules cannot run without a mainframe, but the trade-off is flexibility: mix high-current, high-voltage and dual-channel modules in one chassis, run them independently or in parallel, and synchronise multi-channel sequences. When one chassis isn’t enough, link up to five mainframes (one master + four slaves) for around 7 kW of combined sinking capacity for high-power applications such as multi-output supplies, chargers and battery systems.
PEL-2000A load module lineup
| Module | Channels | Voltage | Current | Power | Best for |
|---|---|---|---|---|---|
| PEL-2020A / 2020B | Dual (L/R) | 0–80 V | 0–2 A / 0–20 A per ch | 100 W × 2 | Dual-rail, general low-power testing |
| PEL-2030A / 2030B | Dual (L/R) | 1–80 V | 0–5 A / 0–40 A | 30 W + 250 W | Mixed low-current + medium-power rails |
| PEL-2040A / 2040B | Single | 0–80 V | 0–7 A / 0–70 A | 350 W | High-current loads, battery packs |
| PEL-2041A / 2041B | Single | 0–500 V | 0–1 A / 0–10 A | 350 W | High-voltage sources |
Each range (low/high) on every module has its own resolution and accuracy; for example the PEL-2040A high range reads back current to 1.4 mA and the PEL-2041A handles up to 500 V. GSAS helps you select the module combination, and the number of slots, that covers your present and near-future test requirements with margin.
Programmable DC load: CC, CR, CV and CP with dynamic operation
In constant-current (CC) mode the load draws a set current regardless of source voltage; constant-resistance (CR) emulates a fixed resistance; constant-voltage (CV / CV+CC) holds a target terminal voltage; and constant-power (CP) sinks a fixed wattage, ideal for verifying a supply at its rated power across its voltage range. CC and CR also run in dynamic mode, alternating between two levels (T1/T2) with step times from 0.025 ms to 30 s and a current slew rate up to 2.8 A/µs, so the PEL-2000A reproduces pulsed and transient current profiles for power-supply transient-response and load-step testing.
Battery load tester and discharge profiling
For battery and energy-storage work, a battery load tester must combine controlled current draw with safe, repeatable sequencing. The PEL-2000A’s CC and CP modes set a precise discharge current or power, while the sequence function and 12 programs of 10 panel-setup memories each let engineers script multi-step discharge profiles, for example stepping current to mimic a real load cycle. A GO/NoGo (pass/fail) judgement flags out-of-limit results automatically, and comprehensive protection guards both the load and the cell or pack under test during long discharge runs.
Protection and interfaces
The PEL-2000A includes six protection modes, Over-Current (OCP), Over-Voltage (OVP), Over-Power (OPP), Over-Temperature (OTP), Reverse-Voltage (RVP) and Under-Voltage (UVP) protection, to safeguard the load and the device under test. For remote control and data acquisition, the PEL-2000A provides USB Device/Host and RS-232C as standard, with GPIB (PEL-001 card) and LAN as options. The PEL-2000B mainframe adds a built-in LAN interface (and RS-485) as standard plus USB flash-drive support, with GPIB still optional, useful when remote bench access or networked logging is required. Both series are cross-compatible after firmware update, so modules and mainframes can be mixed.
Applications
The PEL-2000A Series suits engineering and production teams that need flexible, high-power DC loading:
- Power-supply design and validation: load-regulation, transient-response and constant-power testing across the full output range.
- Battery and charger testing: controlled discharge profiling, charge/discharge characterisation and pack validation.
- Production and incoming inspection: automated sequences with GO/NoGo judgement for repeatable pass/fail screening.
- High-voltage source testing: the 0–500 V PEL-2041A module for high-voltage supplies and converters.
- High-current and multi-output systems: parallel modules and chained mainframes for kilowatt-class loads.
These cover power electronics and EV, battery and energy storage, electronics manufacturing QA and R&D lab environments where configurable DC loading and automated test throughput both matter.
Electronic load price in India: buy the PEL-2000A from GSAS Micro Systems
GSAS Micro Systems is an authorized GW Instek engineering partner in India. We supply the full PEL-2000A and PEL-2000B range, mainframes, every load module and accessories, with configuration guidance, hands-on demonstrations, GST-compliant quotations, calibration with maintained traceability and post-sales application support. Engineering, quality and production teams across Bengaluru, Hyderabad, Chennai, Pune, Mumbai and Delhi NCR rely on GSAS for fast access and local support. Contact GSAS or request a quote to get the PEL-2000A price in India and order with delivery nationwide.
Blog
GW Instek Insights
Emulating Processor Power for Thermal Testing: Why Constant Power
A heat sink or a cold plate is qualified against a watt figure, not a volt figure. This application note explains why a thermal load is driven in constant-power mode, how the bench is built for air and for liquid cooling, and what to confirm before you buy.
CRPS and Rack Power Supply Testing: The Six Tests That Matter
A CRPS module has to hold up under an unbalanced grid, a 0 to 100 percent load step, a surge on the line and a redundancy handover. This application note sets out the six tests, and the one source capability that makes a long feeder reproducible on the bench.
GPU Power Board Testing: DC Input Verification Before Integration
A GPU power delivery board is cheap to reject on a bench and expensive to find in an assembled server. This application note covers the programmable DC input test that screens the board, and the same test applied to incoming server systems.
Related products
More from GW Instek
All GW Instek products →
AEL-5000 Series
GW Instek AEL-5000 programmable AC & DC electronic load, 20 models from 1.875 kW to 22.5 kW per unit, scalable to 180 kW single-phase and a 540 kW three-phase electronic load in parallel, with Turbo Mode and an AC Rectifier Load Mode for regenerative-grade load testing of UPS, inverters, fuses and breakers. Available in India from GSAS Micro Systems, an authorized GW Instek engineering partner.
View AEL-5000 Series →
PEL-5000G Series
GW Instek PEL-5000G high power DC electronic load, a 1200 V programmable DC load with 4 kW to 6 kW per module across 150 V / 600 V / 1200 V families, Turbo Mode for 1.5x current and power, CV-mode parallel operation, Surge and BMS test modes, and 5-digit V/A/W readback. Available in India from GSAS Micro Systems with system sizing, parallel configuration and after-sales support.
View PEL-5000G Series →
PEL-5000C Series
GW Instek PEL-5000C high-power compact programmable DC electronic load, 150V / 600V / 1200V models, 6kW to 24kW per unit, up to 8 units in master/slave parallel for a 192kW electronic load, with CC/CR/CV/CP, dynamic, battery-test and solar-MPPT-test modes for EV charger, EV battery and solar panel validation. The high power DC load India teams choose for battery, charging-station and renewable-energy test, available from GSAS Micro Systems, an authorized GW Instek engineering partner, with application engineering, calibration and local support.
View PEL-5000C Series →FAQ
Common questions about PEL-2000A Series
How much does the PEL-2000A Series cost in India?
Is the PEL-2000A a standalone DC electronic load or a modular system?
What is the difference between the PEL-2000A and PEL-2000B series?
Which PEL-2000A load module do I need for battery, high-current or high-voltage testing?
Can the PEL-2000A simulate dynamic loads and run automated test sequences?
How do I buy the GW Instek PEL-2000A in India?
Interested in PEL-2000A Series?