PEL-2000A Series
Electronic LoadsGW Instek PEL-2000A programmable DC electronic load, a modular, multi-channel DC load (2- or 4-slot mainframe with plug-in modules) covering 0–500 V, up to 70 A and 350 W per module, with CC/CR/CV/CP modes, dynamic and sequence functions, and up to 7 kW system capacity. Available in India from GSAS Micro Systems, the authorized GW Instek engineering partner, with INR/GST quotation, demonstration, calibration and application support.
Architecture
Modular: 2-slot (PEL-2002A) / 4-slot (PEL-2004A) mainframe + plug-in modules
Voltage
0–80 V (modules) / 0–500 V (PEL-2041A)
Current
Up to 0–70 A per module
Power
Up to 350 W per module · 1.4 kVA per mainframe · 7 kW chained
Modes
CC, CR, CV, CV+CC, CP (static & dynamic)
Slew Rate
Up to 2.8 A/µs
Dynamic Mode
25 µs minimum step (T1/T2 0.025 ms–30 s)
Protection
OCP, OVP, OPP, OTP, RVP, UVP
Overview
About PEL-2000A Series
The GW Instek PEL-2000A Series is a modular, multi-channel programmable DC electronic load built for power-supply design, quality inspection and characteristic certification. Instead of a single fixed box, it uses a mainframe-and-module structure: the PEL-2002A holds two load modules and the PEL-2004A holds four. Choose your modules to match the job, and the system covers everything from low-power dual-rail validation up to 0–500 V, 0–70 A and 350 W per module: with a fully loaded mainframe sinking up to 1.4 kVA and up to five linked mainframes reaching about 7 kW of total load capacity.
Every module supports CC, CR, CV, CV+CC and CP operating modes (constant current and constant resistance also run in dynamic mode), making the PEL-2000A a flexible DC electronic load for source validation, transient-response testing and automated production screening.

A modular DC electronic load: mainframe plus plug-in modules
The PEL-2000A is not a standalone load; its strength is configurability. You pick a 2-slot PEL-2002A or 4-slot PEL-2004A mainframe (which holds the master controller, display and interfaces) and then fit the load modules your bench needs. Modules cannot run without a mainframe, but the trade-off is flexibility: mix high-current, high-voltage and dual-channel modules in one chassis, run them independently or in parallel, and synchronise multi-channel sequences. When one chassis isn’t enough, link up to five mainframes (one master + four slaves) for around 7 kW of combined sinking capacity for high-power applications such as multi-output supplies, chargers and battery systems.
PEL-2000A load module lineup
| Module | Channels | Voltage | Current | Power | Best for |
|---|---|---|---|---|---|
| PEL-2020A / 2020B | Dual (L/R) | 0–80 V | 0–2 A / 0–20 A per ch | 100 W × 2 | Dual-rail, general low-power testing |
| PEL-2030A / 2030B | Dual (L/R) | 1–80 V | 0–5 A / 0–40 A | 30 W + 250 W | Mixed low-current + medium-power rails |
| PEL-2040A / 2040B | Single | 0–80 V | 0–7 A / 0–70 A | 350 W | High-current loads, battery packs |
| PEL-2041A / 2041B | Single | 0–500 V | 0–1 A / 0–10 A | 350 W | High-voltage sources |
Each range (low/high) on every module has its own resolution and accuracy; for example the PEL-2040A high range reads back current to 1.4 mA and the PEL-2041A handles up to 500 V. GSAS helps you select the module combination, and the number of slots, that covers your present and near-future test requirements with margin.
Programmable DC load: CC, CR, CV and CP with dynamic operation
In constant-current (CC) mode the load draws a set current regardless of source voltage; constant-resistance (CR) emulates a fixed resistance; constant-voltage (CV / CV+CC) holds a target terminal voltage; and constant-power (CP) sinks a fixed wattage, ideal for verifying a supply at its rated power across its voltage range. CC and CR also run in dynamic mode, alternating between two levels (T1/T2) with step times from 0.025 ms to 30 s and a current slew rate up to 2.8 A/µs, so the PEL-2000A reproduces pulsed and transient current profiles for power-supply transient-response and load-step testing.
Battery load tester and discharge profiling
For battery and energy-storage work, a battery load tester must combine controlled current draw with safe, repeatable sequencing. The PEL-2000A’s CC and CP modes set a precise discharge current or power, while the sequence function and 12 programs of 10 panel-setup memories each let engineers script multi-step discharge profiles, for example stepping current to mimic a real load cycle. A GO/NoGo (pass/fail) judgement flags out-of-limit results automatically, and comprehensive protection guards both the load and the cell or pack under test during long discharge runs.
Protection and interfaces
The PEL-2000A includes six protection modes, Over-Current (OCP), Over-Voltage (OVP), Over-Power (OPP), Over-Temperature (OTP), Reverse-Voltage (RVP) and Under-Voltage (UVP) protection, to safeguard the load and the device under test. For remote control and data acquisition, the PEL-2000A provides USB Device/Host and RS-232C as standard, with GPIB (PEL-001 card) and LAN as options. The PEL-2000B mainframe adds a built-in LAN interface (and RS-485) as standard plus USB flash-drive support, with GPIB still optional, useful when remote bench access or networked logging is required. Both series are cross-compatible after firmware update, so modules and mainframes can be mixed.
Applications
The PEL-2000A Series suits engineering and production teams that need flexible, high-power DC loading:
- Power-supply design and validation: load-regulation, transient-response and constant-power testing across the full output range.
- Battery and charger testing: controlled discharge profiling, charge/discharge characterisation and pack validation.
- Production and incoming inspection: automated sequences with GO/NoGo judgement for repeatable pass/fail screening.
- High-voltage source testing: the 0–500 V PEL-2041A module for high-voltage supplies and converters.
- High-current and multi-output systems: parallel modules and chained mainframes for kilowatt-class loads.
These cover power electronics and EV, battery and energy storage, electronics manufacturing QA and R&D lab environments where configurable DC loading and automated test throughput both matter.
Electronic load price in India: buy the PEL-2000A from GSAS Micro Systems
GSAS Micro Systems is the authorized GW Instek engineering partner in India. We supply the full PEL-2000A and PEL-2000B range, mainframes, every load module and accessories, with configuration guidance, hands-on demonstrations, GST-compliant quotations, calibration with maintained traceability and post-sales application support. Engineering, quality and production teams across Bengaluru, Hyderabad, Chennai, Pune, Mumbai and Delhi NCR rely on GSAS for fast access and local support. Contact GSAS or request a quote to get the PEL-2000A price in India and order with delivery nationwide.
Blog
GW Instek Insights
AI Data Center Testing: Power Shelves, Busbars, Burn-In and Optics
AI racks fail on the bench long before they fail in the field. How AI data center infrastructure is actually tested: server power shelves and CRPS supplies, 48V busbars, battery backup units, DC-DC stages, burn-in, thermal validation, high-speed switches, and optical transceivers, mapped to the GW Instek instruments GSAS supplies across India.
Testing High-Power UPS, Solar Inverters and Power Electronics: Inside the GW Instek AEL-5000 AC/DC Electronic Load
India's UPS, solar-inverter and power-electronics makers need load testing that behaves like the real world: non-linear, high-power and scalable. Here is how the GW Instek AEL-5000 AC/DC electronic load covers it, from 1.875 kW on the bench to 540 kW in a three-phase array.
Automated EV Charger Test Bench in India: GW Instek AC Source, DC Load and Battery Emulator
A walkthrough of an automated test bench that validates a CAN-controlled EV scooter charger across the full Indian grid envelope. GW Instek's APS-7200 AC source, PEL-3111AH DC load and GPP-7250 battery emulator combine with a Total Phase Komodo CAN Duo BMS emulator for unattended, repeatable charger validation, designed, integrated and scripted in India by GSAS.
Related products
More from GW Instek
All GW Instek products →
AEL-5000 Series
GW Instek AEL-5000 programmable AC & DC electronic load, 20 models from 1.875 kW to 22.5 kW per unit, scalable to 180 kW single-phase and a 540 kW three-phase electronic load in parallel, with Turbo Mode and an AC Rectifier Load Mode for regenerative-grade load testing of UPS, inverters, fuses and breakers. Available in India from GSAS Micro Systems, the authorized GW Instek engineering partner.
View AEL-5000 Series →
PEL-5000G Series
GW Instek PEL-5000G high power DC electronic load, a 1200 V programmable DC load with 4 kW to 6 kW per module across 150 V / 600 V / 1200 V families, Turbo Mode for 1.5x current and power, CV-mode parallel operation, Surge and BMS test modes, and 5-digit V/A/W readback. Available in India from GSAS Micro Systems with system sizing, parallel configuration and after-sales support.
View PEL-5000G Series →
PEL-5000C Series
GW Instek PEL-5000C high-power compact programmable DC electronic load, 150V / 600V / 1200V models, 6kW to 24kW per unit, up to 8 units in master/slave parallel for a 192kW electronic load, with CC/CR/CV/CP, dynamic, battery-test and solar-MPPT-test modes for EV charger, EV battery and solar panel validation. The high power DC load India teams choose for battery, charging-station and renewable-energy test, available from GSAS Micro Systems, the authorized GW Instek engineering partner, with application engineering, calibration and local support.
View PEL-5000C Series →FAQ
Common questions about PEL-2000A Series
How much does the PEL-2000A Series cost in India?
Is the PEL-2000A a standalone DC electronic load or a modular system?
What is the difference between the PEL-2000A and PEL-2000B series?
Which PEL-2000A load module do I need for battery, high-current or high-voltage testing?
Can the PEL-2000A simulate dynamic loads and run automated test sequences?
How do I buy the GW Instek PEL-2000A in India?
Interested in PEL-2000A Series?
Get pricing, an evaluation unit, or a technical consultation from our application engineers.