PEL-3000A Series
Electronic LoadsProgrammable DC electronic load with up to 9.45 kW parallel capacity, 7 operating modes, 16A/us slew rate, and Go/NoGo testing. Available in India from GSAS Micro Systems.
Power
Up to 9.45 kW (parallel)
Voltage
0-150V / 0-500V / 0-800V
Slew Rate
Up to 16A/us
Dynamic
0.016 Hz to 20 kHz
Modes
CC/CV/CR/CP/CC+CV/RC+CV/PC+CV
Interface
USB, RS-232, RS-485, LAN
Overview
About PEL-3000A Series
The PEL-3000A Series is a programmable DC electronic load supporting seven operating modes including CC, CV, CR, CP, and combined modes (CC+CV, RC+CV, PC+CV). With a maximum slew rate of 16A/us and dynamic switching from 0.016 Hz to 20 kHz, this series handles demanding transient response testing. The PEL-3000AH variant extends the voltage range to 800V for high-voltage applications, while the PEL-3000AE provides an entry-level option with essential features.
| Model | Voltage | Power | Slew Rate | Target Application |
|---|---|---|---|---|
| PEL-3021A | 0-150V | 175W | 16A/us | Benchtop PSU testing |
| PEL-3031A | 0-150V | 175W | 16A/us | General-purpose loading |
| PEL-3041A | 0-150V | 150W | 16A/us | Mid-power validation |
| PEL-3041AH | 0-800V | High voltage | 16A/us | EV, solar, HV testing |
| PEL-3031AE | 0-150V | 100-500W | Entry-level | Cost-effective loading |
| PEL-3032AE | 0-500V | 100-500W | Entry-level | Mid-voltage entry-level |
| Feature | PEL-3000A / AH | PEL-3000AE |
|---|---|---|
| Operating Modes | 7 modes | 7 modes |
| Go/NoGo Testing | Yes | Not available |
| Normal Sequence Steps | Run program | Up to 1100 steps |
| Fast Sequence Steps | N/A | Up to 1000 steps |
| GPIB | Optional | Not available |
| USB / RS-232 / RS-485 / LAN | Yes | Yes |
The run program function with Go/NoGo judgment enables production-line pass/fail testing with programmable criteria. Adjustable OCP, OPV, and OPP settings protect the device under test, while parallel operation scales capacity up to 9.45 kW for high-power applications.
Engineers working on switch-mode power supplies, DC-DC converters, battery management systems, and renewable energy inverters use the PEL-3000A for load regulation testing, transient response characterization, and automated production verification across a wide voltage range.
Watch the PEL 3000A introduction
GSAS Micro Systems provides the PEL-3000A Series in India with model selection guidance, parallel configuration support, and after-sales calibration.
Blog
GW Instek Insights
AI Data Center Testing: Power Shelves, Busbars, Burn-In and Optics
AI racks fail on the bench long before they fail in the field. How AI data center infrastructure is actually tested: server power shelves and CRPS supplies, 48V busbars, battery backup units, DC-DC stages, burn-in, thermal validation, high-speed switches, and optical transceivers, mapped to the GW Instek instruments GSAS supplies across India.
Testing High-Power UPS, Solar Inverters and Power Electronics: Inside the GW Instek AEL-5000 AC/DC Electronic Load
India's UPS, solar-inverter and power-electronics makers need load testing that behaves like the real world: non-linear, high-power and scalable. Here is how the GW Instek AEL-5000 AC/DC electronic load covers it, from 1.875 kW on the bench to 540 kW in a three-phase array.
Automated EV Charger Test Bench in India: GW Instek AC Source, DC Load and Battery Emulator
A walkthrough of an automated test bench that validates a CAN-controlled EV scooter charger across the full Indian grid envelope. GW Instek's APS-7200 AC source, PEL-3111AH DC load and GPP-7250 battery emulator combine with a Total Phase Komodo CAN Duo BMS emulator for unattended, repeatable charger validation, designed, integrated and scripted in India by GSAS.
Related products
More from GW Instek
All GW Instek products →
AEL-5000 Series
GW Instek AEL-5000 programmable AC & DC electronic load, 20 models from 1.875 kW to 22.5 kW per unit, scalable to 180 kW single-phase and a 540 kW three-phase electronic load in parallel, with Turbo Mode and an AC Rectifier Load Mode for regenerative-grade load testing of UPS, inverters, fuses and breakers. Available in India from GSAS Micro Systems, the authorized GW Instek engineering partner.
View AEL-5000 Series →
PEL-5000G Series
GW Instek PEL-5000G high power DC electronic load, a 1200 V programmable DC load with 4 kW to 6 kW per module across 150 V / 600 V / 1200 V families, Turbo Mode for 1.5x current and power, CV-mode parallel operation, Surge and BMS test modes, and 5-digit V/A/W readback. Available in India from GSAS Micro Systems with system sizing, parallel configuration and after-sales support.
View PEL-5000G Series →
PEL-5000C Series
GW Instek PEL-5000C high-power compact programmable DC electronic load, 150V / 600V / 1200V models, 6kW to 24kW per unit, up to 8 units in master/slave parallel for a 192kW electronic load, with CC/CR/CV/CP, dynamic, battery-test and solar-MPPT-test modes for EV charger, EV battery and solar panel validation. The high power DC load India teams choose for battery, charging-station and renewable-energy test, available from GSAS Micro Systems, the authorized GW Instek engineering partner, with application engineering, calibration and local support.
View PEL-5000C Series →Interested in PEL-3000A Series?
Get pricing, an evaluation unit, or a technical consultation from our application engineers.