Joulescope (Maryland, USA) builds precision DC energy analyzers purpose-built for embedded power profiling. Traditional multimeters and oscilloscope-based shunt measurements lack the dynamic range and sampling continuity to capture devices that transition between nanowatt sleep states and ampere-level active bursts in microseconds. The current-generation Joulescope JS320 solves this with 36-bit-equivalent dynamic range, 1 Msps 24-bit simultaneous current and voltage sampling, and gap-free Enwavify v2 autoranging, making it the reference instrument for IoT power optimization, battery-life validation, and energy-harvesting design.
Indian engineering teams developing BLE sensors, LoRaWAN nodes, wearables, and industrial edge devices rely on the JS320 to verify that firmware power budgets match real-world behavior. GSAS has been India's authorized Joulescope partner since 2021, providing instrument supply, evaluation programs, and measurement methodology guidance across six offices, Bengaluru, Chennai, Hyderabad, Delhi NCR, Mumbai, and Pune.
Latest Insights
Product Families
Joulescope Products by Category
Joulescope JS320: Buy in India
Joulescope JS320
The third-generation precision DC energy analyzer. It measures current down to 0.1 nA resolution, up to 3 A continuous (10 A pulses), while simultaneously measuring voltage to +/-15 V for real-time power, energy, and charge. A 24-bit, 1 Msps measurement path and 36-bit-equivalent dynamic range capture sleep-mode draw, ISR wake-ups, radio bursts, and inrush events in one uninterrupted trace. Enwavify v2 autoranging switches ranges in 1 microsecond with zero dead time, and now measures using any current range during transitions for cleaner low-current results.
JS320 Specifications
| Specification | JS320 |
|---|---|
| Current | 0.1 nA resolution, +/-3 A continuous, 10 A pulses |
| Dynamic Range | 36-bit equivalent (64-bit internal digital path) |
| Sampling Rate | 1 Msps, 24-bit simultaneous current and voltage (18 ENOB) |
| Bandwidth | 200 kHz |
| Voltage Range | +/-15 V |
| Range Switching | 1 microsecond (Enwavify v2, zero gaps, any range during transitions) |
| Simultaneous Measurements | Current, Voltage, Power, Energy, Charge |
| Isolation | Sensor ports electrically isolated from USB |
| Software | Joulescope UI + Python API (Windows, macOS, Linux) |
| Variants | JS320-K000 (factory calibration), JS320-K001 (ISO 17025 NIST-traceable) |
Eval Kit and Front Panels: work with the JS320
Eval Kit
The accessory bundle, banana-jack cables, board-header adapters, flying leads, and a USB-C cable, that gets a Joulescope onto your bench and measuring out of the box. A convenient starting point for teams new to precision energy analysis; the accessories carry over to the JS320.
Interchangeable Front Panels
Adapt the instrument to different measurement setups: USB, BNC, Safety Banana Jack, and Binding Post. The front panels are interchangeable and compatible with the JS320, from bench probing through rack-mount automated-test integration.
Software and Python API
Open-Source Software, Free Forever
The Joulescope UI displays real-time waveforms with multimeter and oscilloscope views, statistical analysis, and energy accumulation. Zoom from hours of capture down to individual microsecond events. The Python API enables automated power regression testing in CI/CD pipelines. Export data in CSV, JLS, and binary formats for post-processing in MATLAB, Python, or custom toolchains.
JS320-K001: ISO 17025 NIST-Traceable Calibration
The JS320-K001 is the accredited-calibration variant of the Joulescope JS320. It ships with an ISO 17025:2017 NIST-traceable calibration certificate, for teams that need documented measurement traceability.
Defence procurement, medical device validation, and automotive workflows often demand formal calibration documentation. The JS320-K001 meets these requirements while retaining the full JS320 measurement capability; the instrument and its performance are identical to the JS320-K000, and the calibration is the only difference.
Key points:
- ISO 17025:2017 NIST-traceable calibration certificate included with every JS320-K001 unit
- Same instrument and measurement performance as the JS320-K000; only the calibration differs
- Recalibration and validation for JS320 units in the field available through GSAS via a partner lab in India
Ideal for validation labs, quality departments, and regulated environments. For India pricing on either variant, request a quote.
Why GSAS
Why Choose GSAS as Your Joulescope Engineering Partner
5+
Years as Joulescope Partner
9+
Decades Dynamic Range
India-wide
Local Support
- Evaluation unit programs: hands-on JS320 demos for engineering teams before purchase
- Power profiling methodology workshops: measurement setup, fixture design, and result interpretation
- Python API training: scripted automation, CI/CD integration, and power regression testing
- Application engineering: connection strategy consulting for specific target hardware and test environments
- Local support available from Bengaluru, Chennai, Hyderabad, Delhi NCR, Mumbai, and Pune
- Local procurement: INR invoicing on the JS320, Eval Kit, and Front Panel accessories with GeM, SAP Ariba, Coupa, and TReDS support
Joulescope's India design and customer footprint clusters in Bengaluru, India's largest embedded systems and semiconductor design hub. Read our Bengaluru engineering ecosystem guide →
Videos
Joulescope Video Library
Electronica 2025: Joulescope at GSAS
Unlock Power Profiling: Peak Power vs Duration
Joulescope Demo at Embedded World North America 2024
Inrush Current Testing with Joulescope
Available across India
Joulescope by City
Blog
Joulescope Insights
Battery Discharge Profiling for Coin Cell Devices: From CR2032 to 10-Year Life
How to profile and optimize coin cell battery discharge for ultra-low-power embedded devices, CR2032 capacity characteristics, pulse load effects, and measurement techniques using the Joulescope JS220.
BLE Power Profiling: Measuring Bluetooth Low Energy Current With Joulescope
How to measure and optimize BLE device power consumption, advertising, connection events, sleep current, and peripheral power, using the Joulescope JS220 for precise energy-per-event analysis.
Energy Harvesting and Power Measurement: Designing Self-Powered IoT Devices
How to measure and validate the energy budget of energy-harvesting IoT devices, balancing harvested power against consumed power using the Joulescope JS220 for continuous energy balance monitoring.
IoT Battery Life Testing: A Practical Methodology for Indian Product Teams
How to measure, predict, and validate battery life for IoT devices, from duty cycle characterization through accelerated testing to statistical confidence, using the Joulescope JS220 as the measurement backbone.
IoT Power Consumption Trends: Why Indian Product Teams Need Better Measurement
The IoT industry is in a sustained race to reduce device power consumption.
Joulescope JS220: Hardware Architecture and Software Ecosystem Deep Dive
Inside the Joulescope JS220 hardware, how Enwavify autoranging, dual 16-bit ADCs, and low burden voltage enable nanoamp-to-amp measurement, plus the Joulescope UI, Python API, and CI/CD integration capabilities.
Automating Power Measurement With the Joulescope Python API
Manual power measurement, connecting the Joulescope, starting a capture, triggering the device, reading the results from the UI, works well for one-of...
Joulescope vs Digital Multimeter: Why Your DMM Cannot Measure IoT Power Consumption
A technical comparison of the Joulescope JS220 and benchtop digital multimeters for embedded device power measurement, dynamic range, bandwidth, burden voltage, and why the DMM's reading is wrong for duty-cycled devices.
Joulescope vs Bench Power Analyzers: Choosing the Right Tool for Embedded Power Measurement
How the Joulescope JS220 compares to traditional bench power analyzers and source-measure units for embedded device power profiling, dynamic range, form factor, cost, and workflow differences.
Power Profiling Tutorial: Reducing Firmware Power Consumption Step by Step
A step-by-step tutorial on using the Joulescope JS220 to identify and fix firmware power bugs, from GPIO misconfiguration to unnecessary peripheral clocks, with before-and-after measurement results.
Battery Life Prediction for Embedded Devices: Measurement-Based Validation with Joulescope
Why spreadsheet-based battery life estimates fail and how measurement-based validation with the Joulescope JS220 produces reliable predictions. Methodology for statistical confidence and product validation reports.
IoT Device Power Profiling with Joulescope JS220: From Nanoamps to Amps
How to measure IoT device power consumption across sleep, idle, and active states using the Joulescope JS220. Practical methodology for BLE sensors, LoRaWAN nodes, and battery-powered edge devices.
Ready to Get Started with Joulescope?
Get pricing, evaluation units, or a technical consultation from our application engineers across India.